Registruokitės, kad atrakintumėte savo išskirtines B2B kainas ir pradėtumėte apsipirkinėti. Užsiregistruokite dabar!
MD01 image 1
MD01 image 2
MD01 image 3
MD01 image 4
MD01 image 5
MD01 image 6
KA4256Z Measurement and metering transformer board, Field width: 3, Rows: 0, 1050 mm x 750 mm x 160 mm, IP2XC image 7
MD01 thumbnail 1
MD01 thumbnail 2
MD01 thumbnail 3
MD01 thumbnail 4
MD01 thumbnail 5
MD01 thumbnail 6
KA4256Z Measurement and metering transformer board, Field width: 3, Rows: 0, 1050 mm x 750 mm x 160 mm, IP2XC thumbnail 7

KA4256Z Mess-u.Wandlerfeld H3/B3

Yra sandėlyje: Ne Pardavėjo atsargos: Ne Minimalus užsakymo kiekis: 1
Kaina (be PVM):
1 930,08 €
Ši kaina galioja iki 31.12.24
EAN: 4011617350750
MPN: 2CPX035075R9999
Dėžė: 1

Technical Information

Prekės būklė Nauja
Gamintojo pavadinimas KA4256Z Measurement and metering transformer board, Field width: 3, Rows: 0, 1050 mm x 750 mm x 160 mm, IP2XC
Prekės ženklas ABB
Kategorijos Elektros skydai
Suderintos sistemos kodas 8537 1098 00
Spalva Pilkas
Plotis 750 mm
Modelis Vieno aukšto
Aukštis 1050 mm
RAL numeris 7035
Su montavimo plokšte No
Jungties vieta 300 mm
Su laidynu Yes
Modulinių tarpų skaičius plotyje 36
TSG panelių skaičius 1
Paskirstytojo eilių skaičius 0
Matuoklio dėžių skaičius 1
Apatinė jungties erdvė Su DIN bėgiais (viršutiniai bėgiai)
Saugos laipsnis (IP) IP2XC
Pagrindinio jungiklio nominali srovė 250 A
Dangčio modelis Uždarytas su spaudavimu

Pakavimo informacija

Pakavimo lygis 1 4011617350750

Atsisiuntimai

Aprašymas

Measurement and metering transformer board, fully assembled module, with Metering cross, for the internal use, degree of protection IP2XC, applicable standards: EN 61439-1, EN 61439-2, Rated operational voltage 415V AC 50/60 Hz, rated current 200 A, Rated current of the assembly of switchgear and controlgear InA 250 A, in RAL 7035, dimensions in mm (H x W x D): 1050 x 750 x 160, Earthing system TN-S, 5-pole, Number of SG spaces 1, Number of transformer meter spaces 1, Pre-wired according requirements DSO, voltage path 3 low voltage path switches B10/25kA overvoltage path category 3, busbar system Cu busbars mm 5-pole, current transformer range CT mounting pad with CT rail 30 x 5 mm, parting point after the current transformer Switch 250 A / 3-pole (M8), primary wiring Cu-Busbar 30 x 5 mm, Connection N+PE (M8), Note: In case short circuit is > 25 kA, Backup protection required for voltage path circuit. Short circuit value to be obtained from DSO. Busbar terminals should be ordered seperately, Grid unit 7 GU, Overall height 3, panel width 3, Space units 252, covers out of Plastic, Quick sealable connection, RAL 7035