Register to unlock your exclusive B2B prices. Register now
MD01 image 1
Acti9 ID K - residual current circuit breaker - 4P - 40A - 300mA - type A image 2
Acti9 ID K - residual current circuit breaker - 4P - 40A - 300mA - type A image 3
Acti9 ID K - residual current circuit breaker - 4P - 40A - 300mA - type A image 4

Acti9 ID K - residual current circuit breaker - 4P - 40A - 300mA - type A

Sandėlyje esančios prekės kaina (be PVM):
33,47 €
Ši kaina galioja iki 2024-12-24
Kaina už m: 33,47 €
EAN: 3606480482809
MPN: A9Z04440
Mūsų sandėlis: Ne Pardavėjo atsargos: Taip
Už pakuotę: 1 Už dėžę: 27 Už padėklą: N/A
Techniniai duomenys
Prekės būklė Nauja
Gamintojo pavadinimas Acti9 ID K - residual current circuit breaker - 4P - 40A - 300mA - type A
Prekės ženklas Schneider Electric
Kategorijos Apsauga nuo nuotėkio
Montavimo metodas DIN bėgis
Įtampos tipas Kintamoji srovė
Suprojektuotas gylis 44 mm
Nustatyta srovė 40 A
Nustatyta įtampa 400 V
Nominali izoliacinė įtampa Ui 440 V
Polių skaičius 4
Nominali gedimo srovė 300 A
Srovės nutekėjimo tipas A
Selektyvinė apsauga No
Trumpo jungimosi sistemos išjungimo pajėgumas (lcw) 10 kA
Srovės padidėjimo intensyvumas 0.25 kA
Užterštumo laipsnis 2
Modulinių tarpų skaičius plotyje 4
Trumpalaikis ribinis delsos atjungimas No
Apsaugotas nuo sprogimo No
Dažnis 50/60 Hz
Saugos laipsnis (IP) IP20
Prijungiamo laidininko kryžminės sekcijos vientisa šerdis 1-35 mm²
Prijungiamo laidininko kryžminės sekcijos įvairialypis laidynas 1-25 mm²
Su užblokavimo įrenginiu No
Aplinkos temperatūra operaciniu metu -25-40 °C
Galima papildoma įranga Yes
Nurodytoji atlaikoma impulsinė įtampa 4 kV
Pakavimo informacija
Pakavimo lygis 1 3606480482809
Pakavimo lygis 2 3606480482807
Downloads
Aprašymas
This Acti9 ID K product is a biconnect residual current circuit breaker (RCCB). It is a 4P circuit breaker with 40A In rated current, 300mA earth leakage sensitivity and A type protection class. This product protects against electrical shock by indirect contact and fire hazards. There is a test button used to check the residual current device is operating correctly. The connection is made downstream by biconnect comb busbar or upstream/downstream by tunnel terminals. This product is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 500A. The (Inc/IΔc) conditional rated short circuit current is 4.5kA. It has an electrical endurance going up to 2000 cycles and a mechanical endurance going up to 5000 cycles. The Ue operational voltage is 380VAC to 415VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 8. The product colour is white (RAL9003). The dimensions are (W) 72mm x (H) 81mm x (D) 68mm. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -25°C to 40°C. The storage temperature is from -30°C to 70°C.