RS485 bus wireless three-phase energy meter, MID approval image 1

RS485 bus wireless three-phase energy meter, MID approval

Sandėlyje esančios prekės kaina (be PVM):
171,25 €
Ši kaina galioja iki 2024-12-31
Kaina už m: 171,25 €
EAN: 4010312501450
MPN: 28305712
Mūsų sandėlis: Ne Pardavėjo atsargos: Ne
Už pakuotę: 1 Už dėžę: 1 Už padėklą: N/A
Techniniai duomenys
Prekės būklė Nauja
Gamintojo pavadinimas RS485 bus wireless three-phase energy meter, MID approval
Prekės ženklas ELTAKO
Kategorijos Elektros skaitikliai
Kilmės šalis CN
Suderintos sistemos kodas 9028 3019 00
Montavimo metodas DRA
Plotis 70 mm
Aukštis 82 mm
Gylis 58 mm
Dažnio diapazonas 50 Hz
Maks. srovė (Imax) 6 A
Modulinių tarpų skaičius plotyje 4
Saugos laipsnis (IP) IP20
Poliškumas Keturgyslis laidas
Nominali įtampa (Un) N-L 230 V
Nominali srovė (In) 5 A
Pakavimo informacija
Pakavimo lygis 1 4010312501450, 4010312501450
Pakavimo lygis 2 4010312501450
Downloads
Kiti techniniai duomenys
Modelis Matavimo transformatorius
Tinka Pirkti
Rodmens tipas Skaitmeninis
Bendras skaičius (skaitiklis) 7
Matuoklio tipas Elektroninis
Sąsajos tipas RS-485
Kilovatvalandžių skaitiklio energijos tipo versija Efektinė galia
Kilovatvalandžių skaitiklio tarifinis modelis Vieno dažnio
Tarifo kontrolė Išorinis
Išleidimo mechanizmas Yes
Kalibruotas Yes
Patvirtinimas Matavimo priemonių direktyva
Tikslumo klasė B
Apkrovos profilio matavimas -
EEC40 parašas -
Su blokavimo kodu -
Nominali įtampa (Un) L-L 400 V
Aprašymas
RS485 bus wireless three-phase energy meter with settable CT ratio and MID. Maximum current 3x5A. Standby loss 0.8W at L1 and only 0.5 W at L2 and L3 each. Modulair device for DIN-EN 60715 TH35 rail mounting in distribution cabinets with IP51 protection class. 4 modules = 70mm wide and 58mm deep. Accuracy class B (1%). With RS485 interface. This three-phase energy meter measures active energy by means of the ­current between input and output. The internal power consumption of 0.8W or 0.5W active power per path is neither metered nor indicated. 1, 2 or 3 phase conductors with max. currents up to 5 A can be connected. The inrush current is 10mA. The terminals L1 and N must always be connected. Connection to the Eltako RS485 bus via a FBA14 by means of a 2-wire screened bus line (e.g. telephone line). The meter reading and the momentary capacity are transferred to the bus – e.g. for transfer to an external computer or a Professional Smart Home controller – and is also transferred to the wireless network via the FAM14. For this it is necessary that a device address is assigned from the wireless antenna module FAM14, according to the operating instructions. The 7 segment LC display is also legible twice within a period of 2 weeks without power supply. The power consumption is displayed with a LED flashing 10 times per kWh next to the display. On the right next to the display are the keys MODE and SELECT. Press them to scroll through the menu. First the background lighting switches on. The display then shows the total active energy, the active energy of the resettable memory as well as the instantaneous values of consumption, voltage and current per phase. The CT ratio can also be set. It is set to 5:5 at the factory and blocked with a bridge over the terminals which are marked with 'JUMPER'. To adjust the CT ratio to the installed transformer remove the bridge and reset the energy meter according to the operation manual. Then block it again with the bridge. Adjustable current transformer ratios: 5:5, 50:5, 100:5, 150:5, 200:5, 250:5, 300:5, 400:5, 500:5, 600:5, 750:5, 1000:5, 1250:5 and 1500:5. Error message (false): When the phase conductor is missing or the current direction is wrong false and the corresponding phase conductor are indicated on the display. Important! Before working on the current transformers disconnect the voltage paths of the energy meters.