Three-phase energy meter, without approval image 1

Three-phase energy meter, without approval

Sandėlyje esančios prekės kaina (be PVM):
95,00 €
Ši kaina galioja iki 2024-12-31
Kaina už m: 95,00 €
EAN: 4010312501719
MPN: 28380615
Mūsų sandėlis: Ne Pardavėjo atsargos: Ne
Už pakuotę: 1 Už dėžę: 1 Už padėklą: N/A
Techniniai duomenys
Prekės būklė Nauja
Gamintojo pavadinimas Three-phase energy meter, without approval
Prekės ženklas ELTAKO
Kategorijos Elektros skaitikliai
Kilmės šalis CN
Suderintos sistemos kodas 9028 3019 00
Montavimo metodas DRA
Plotis 70 mm
Aukštis 82 mm
Gylis 58 mm
Dažnio diapazonas 50 Hz
Maks. srovė (Imax) 80 A
Modulinių tarpų skaičius plotyje 4
Saugos laipsnis (IP) IP20
Impulsų dažnis 1000 Imp/kWh (kvarh)
Poliškumas Keturgyslis laidas
Nominali įtampa (Un) N-L 230 V
Nominali srovė (In) 10 A
Pakavimo informacija
Pakavimo lygis 1 4010312501719, 4010312501719
Pakavimo lygis 2 4010312501719
Downloads
Kiti techniniai duomenys
Modelis Tiesioginis matavimas
Tinka Pirkimas / pristatymas
Rodmens tipas Skaitmeninis
Bendras skaičius (skaitiklis) 7
Matuoklio tipas Elektroninis
Sąsajos tipas Kita
Kilovatvalandžių skaitiklio energijos tipo versija Efektinė galia
Kilovatvalandžių skaitiklio tarifinis modelis Du tarifai
Išleidimo mechanizmas Yes
Kalibruotas No
Impulsinė išvestis Optika
Impulsų tipas S0
Tikslumo klasė B
Apkrovos profilio matavimas -
EEC40 parašas -
Su blokavimo kodu -
Nominali įtampa (Un) L-L 400 V
Aprašymas
Maximum current 3x80A. Standby loss 0.5 watt per path only. Modular device for DIN-EN 60715 TH35 rail mounting. 4 modules = 70mm wide and 58mm deep. Accuracy class B (1%). With S0 interface. It measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power per path is neither metered nor indicated. Like all meters without ­declaration of conformity (e.g. MID), this meter is not permitted for billing. 1, 2 or 3 phase conductors with max. currents up to 80A can be connected. The inrush current is 40mA. The N terminal must always be connected. The 7 segment LC display is also legible twice within a period of 2 weeks without power supply. Power consumption is shown by a bar flashing at a rate of 100 times per kWh. Designed as standard for using as double-tariff meter: Switch over to a second tariff by applying 230V to terminals E1/E2. On the right next to the display are the keys MODE and SELECT. Press them to scroll through the menu according to the operation manual. First the background lighting switches on. The display then shows the total active energy per tariff, the active energy per resettable memory RS1 or RS2, and the instantaneous values of consumption, voltage and current per phase. Error message (false): When the phase conductor is missing or the current direction is wrong 'false' and the corresponding phase conductor are indicated on the display.