Register to unlock your exclusive B2B prices. Register now
M-bus three-phase energy meter, MID approval image 1

M-bus three-phase energy meter, MID approval

Sandėlyje esančios prekės kaina (be PVM):
199,59 €
Ši kaina galioja iki 2024-12-31
Kaina už m: 199,59 €
EAN: 4010312501726
MPN: 28380512
Mūsų sandėlis: Ne Pardavėjo atsargos: Ne
Už pakuotę: 1 Už dėžę: 1 Už padėklą: N/A
Techniniai duomenys
Prekės būklė Nauja
Gamintojo pavadinimas M-bus three-phase energy meter, MID approval
Prekės ženklas ELTAKO
Kategorijos Elektros skaitikliai
Kilmės šalis CN
Suderintos sistemos kodas 9028 3019 00
Montavimo metodas DRA
Plotis 70 mm
Aukštis 82 mm
Gylis 58 mm
Dažnio diapazonas 50 Hz
Maks. srovė (Imax) 80 A
Modulinių tarpų skaičius plotyje 4
Saugos laipsnis (IP) IP20
Poliškumas Keturgyslis laidas
Nominali įtampa (Un) N-L 230 V
Nominali srovė (In) 10 A
Pakavimo informacija
Pakavimo lygis 1 4010312501726, 4010312501726
Pakavimo lygis 2 4010312501726
Downloads
Kiti techniniai duomenys
Modelis Tiesioginis matavimas
Tinka Pirkti
Rodmens tipas Skaitmeninis
Bendras skaičius (skaitiklis) 7
Matuoklio tipas Elektroninis
Sąsajos tipas M šyna
Kilovatvalandžių skaitiklio energijos tipo versija Efektinė galia
Kilovatvalandžių skaitiklio tarifinis modelis Du tarifai
Tarifo kontrolė Išorinis
Išleidimo mechanizmas Yes
Kalibruotas Yes
Patvirtinimas Matavimo priemonių direktyva
Tikslumo klasė B
Apkrovos profilio matavimas -
EEC40 parašas -
Su blokavimo kodu -
Nominali įtampa (Un) L-L 400 V
Aprašymas
M-bus three-phase energy meter. Maximum current 3x80A. Standby loss 0.5 watt per path only. Modular device for DIN-EN 60715 TH35 rail mounting. 4 modules = 70mm wide and 58mm deep. Accuracy class B (1%). With M-bus interface. It measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power per path is neither metered nor indicated. 1, 2 or 3 phase conductors with max. currents up to 80A can be connected. The inrush current is 4OmA. The N terminal must always be connected. The 7 segment LC display is also legible twice within a period of 2 weeks without power supply. Power consumption is indicated by an LED flashing at a rate of 1000 times per KWh. Designed as standard for using as double-tariff meter: Switch over to a second tariff by applying 230V to terminals E1/E2. On the right next to the display are the keys MODE and SELECT. Press them to scroll through the menu. First the background lighting switches on. The display then shows the total active energy per tariff, the active energy of the resettable memory RS1 or RS2 as well as the instantaneous values of ­consumption, voltage and current per phase. Error message (false): When the phase conductor is missing or the current direction is wrong false and the corresponding phase conductor are indicated on the display. M-bus data transfer: On read-out all values are transferred in a telegram. The following telegrams are supported: - Initialisation: SND_NKE, Reply: ACK. - Read out meter: REQ_UD2, Reply: RSP_UD. - Change primary address: SND_UD, Reply: ACK. - Reset RS1: SND_UD, Reply: ACK. - Slave selection for the secondary address Reply: ACK. The device does not reply to unknown requests: The transfer rate is detected automatically. The device has a voltage monitor. In case of voltage loss, all registers are saved in the EEPROM. Changing the M-bus primary address: To change the M-bus primary address, hold down SELECT for 3s. In the menu that appears, press MODE to increment the address by 10. Press SELECT to increment by 1. When the required primary address is set, wait until the main menu reappears. Secondary address: It is possible to communicate with the energy meters according to the standard EN13757 using the secondary address. The use of wild cards is possible. For details refer to the operating instructions at www.eltako.com.