Register to unlock your exclusive B2B prices. Register now
MD01 image 1
CDS - three phase load-shedding contactor - 1 channel per phase image 2
CDS - three phase load-shedding contactor - 1 channel per phase image 3
CDS - three phase load-shedding contactor - 1 channel per phase image 4

CDS - three phase load-shedding contactor - 1 channel per phase

In stock price (excl. VAT):
308,22 €
This price is valid until 2024-12-24
Price per m: 308,22 €
EAN: 3606480376870
MPN: A9C15913
Our warehouse: No Vendor stock: No
Per package: 1 Per box: 18 Per pallet: N/A
Technical data
Item condition New
Manufacture name CDS - three phase load-shedding contactor - 1 channel per phase
Brand Schneider Electric
Categories Relays
Country of origin FR
Mounting method DIN rail
Voltage type AC
Built-in depth 67 mm
Rated voltage 230 V
Width in number of modular spacings 8
Rated current Iu 5-90 A
Just-operate current 5-90 A
Rated current (control contacts) 1 A
Electrical lifespan (control contacts) 0 c (contacts)
Max. switching power (control contacts) 0 VA
Max. time-delayed switch-off 0 ms
Max. continuous current 0 A
Max. electrical switching cycles 0 c/h
Max. switching voltage (control contacts) 250 V
Mechanical lifetime (control contacts) 0 c (contacts)
Degree of protection (IP) IP20
Number of contacts as normally closed contact 3
Number of contacts as normally open contact 0
Number of contacts as change-over contact 0
Packing details
Packing level 1 3606480376870
Packing level 2 3606480376878
Downloads
Description
This Acti9 CDS is a three-phase load-shedder for 3 poles installation with 1 relay per phase. When the consumption exceeds the selected threshold, it temporarily cuts off the power supply to non-priority circuits. It increases the number of loads without modifying the installed power. The load-shedding and restoration are done separately phase by phase. The load-shedding time is 5mn for each channel. This device reduces the installed power and prevents nuisance tripping of the upstream circuit breaker. The Iu Rated current is 5A to 90A. The Rated current (control contacts) is 1A. The Ui insulation voltage is 230VAC. The Ue operating voltage is 415VAC +/- 10%. The operating frequency is 50Hz or 60Hz. The power consumption is 12VA. The active power is 20kW maximum. The connection is done with rigid coper cables 10 to 50mm² or Flexible or with ferrule copper cables 10 to 35mm². The dimensions are (W) 144mm x (H) 77mm x (D) 60mm. The width in 9mm pitches is 16. The weight is 600g. The degree of protection is IP20 and IP40 for a device in modular enclosure. The Operating temperature is -5°C to +50°C. The Storage temperature is -40°C to +70°C. It complies with NF C 61.750 and EN 500.81.1 standards.