Register to unlock your exclusive B2B prices. Register now
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 1
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 2
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 3
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 4
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 5
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 6
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 7
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 8
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 9
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 10
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 11
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 12
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 13
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 14
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 15
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 16
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 17

I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in

In stock price (excl. VAT):
104,59 €
This price is valid until 2024-12-24
Price per m: 104,59 €
EAN: 4015081940950
MPN: 197517
Our warehouse: No Vendor stock: No
Per package: 1 Per box: N/A
Technical data
Item condition New
Manufacture name I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in
Brand EATON
Categories Programmable logic controllers
Country of origin EE
Harmonized System Code 8537 1091 00
Width 36 mm
Height 90 mm
Depth 58 mm
Expandable No
Switching current 0.5 A
With time switch clock No
With display No
Suitable for safety functions No
Number of digital inputs 0
Number of digital outputs 0
Number of analogue inputs 4
Number of analogue outputs 0
Voltage type of supply voltage DC
Supporting protocol for LON No
Number of HW-interfaces industrial Ethernet 0
Number of HW-interfaces RS-232 0
Number of HW-interfaces RS-422 0
Number of HW-interfaces RS-485 0
Number of HW-interfaces serial TTY 0
Number of HW-interfaces USB 0
Number of HW-interfaces parallel 0
Number of HW-interfaces other 0
With optical interface No
Supporting protocol for TCP/IP No
Supporting protocol for ASI No
Supporting protocol for PROFIBUS No
Supporting protocol for CAN No
Supporting protocol for INTERBUS No
Supporting protocol for KNX No
Supporting protocol for Modbus Yes
Supporting protocol for Data-Highway No
Supporting protocol for DeviceNet No
Supporting protocol for SUCONET No
Supporting protocol for other bus systems No
Redundancy No
With relay output No
Rail mounting possible Yes
Explosion safety category for gas None
Explosion safety category for dust None
Appendant operation agent (Ex ia) No
Appendant operation agent (Ex ib) No
Degree of protection (IP) IP20
Supporting protocol for SERCOS No
Supporting protocol for INTERBUS-Safety No
Number of interfaces PROFINET 0
Number of HW-interfaces Wireless 0
Front built-in possible No
Rack-assembly possible No
Wall mounting/direct mounting No
Expansion device No
Radio standard Bluetooth No
Radio standard Wi-Fi 802.11 No
Basic device No
IO link master No
Performance level according to EN ISO 13849-1 None
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for EtherNet/IP No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for PROFINET CBA No
Supporting protocol for PROFINET IO No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Supply voltage AC 50 Hz 0 V
Supply voltage AC 60 Hz 0 V
Supply voltage DC 20.4-28.8 V
Radio standard GPRS No
Radio standard GSM No
Radio standard UMTS No
SIL according to IEC 61508 None
Packing details
Packing level 1 4015081940950
Description
I/O expansion for control relays in the easyE4 series with a rated operating voltage of 24 VDC. This expansion provides 4 analog inputs that can be used for the Pt100, Pt1000 or Ni1000 resistance temperature detectors. The Pt100, Pt1000 or Ni1000 inputs are suitable for two- and three-wire connections. Connections are established using push-in terminals. The connection to the control relay or any other expansion in the easyE4 series is established using the EASY-E4-CONNECT1 connector (item 197225), which is included as standard.

Similar items

Accessories

Similar items

Suitable for

Similar items
4015081940844 4015081940851 4015081940868 4015081940875
Accessories
4015081940844 4015081940851 4015081940868 4015081940875
Similar items
4015081940837 4015081940868 4015081940851 4015080613602
Suitable for
4015081940844 4015081940851 4015081940875 4015081940868