Register to unlock your exclusive B2B prices. Register now
Lightning current and surge arresters kit, TN-S/TT kit, 1+NPE image 1
Lightning current and surge arresters kit, TN-S/TT kit, 1+NPE image 2
Lightning current and surge arresters kit, TN-S/TT kit, 1+NPE image 3
Lightning current and surge arresters kit, TN-S/TT kit, 1+NPE image 4
Lightning current and surge arresters kit, TN-S/TT kit, 1+NPE image 5
Lightning current and surge arresters kit, TN-S/TT kit, 1+NPE image 6
Lightning current and surge arresters kit, TN-S/TT kit, 1+NPE image 7
Lightning current and surge arresters kit, TN-S/TT kit, 1+NPE image 8
Lightning current and surge arresters kit, TN-S/TT kit, 1+NPE image 9
Lightning current and surge arresters kit, TN-S/TT kit, 1+NPE image 10
Lightning current and surge arresters kit, TN-S/TT kit, 1+NPE image 11

Lightning current and surge arresters kit, TN-S/TT kit, 1+NPE

In stock price (excl. VAT):
127,01 €
This price is valid until 2024-12-31
Price per m: 127,01 €
EAN: 4015081549221
MPN: 158334
Our warehouse: No Vendor stock: No
Per package: 1 Per box: 30 Per pallet: N/A
Technical data
Item condition New
Manufacture name Lightning current and surge arresters kit, TN-S/TT kit, 1+NPE
Brand EATON
Categories Lighting protection
Country of origin RO
Harmonized System Code 8536 5080 00
Mounting method DIN rail (top hat rail) 35 mm
Lightning impulse current (10/350 µs) 12.500 kA
Number of poles 2.000
Construction size Other
Voltage protection level 0.000 kV
Remote signalling No
Follow current extinguishing capability 0.000 kA
Max. continuous voltage AC 280.000 V
Nominal voltage AC 280.000 V
Nominal voltage DC 0.000 V
Test class Type 1 + 2
Voltage protection level L-N 1.500 kV
Signalling at the device Optic
Max. continuous voltage DC 0.000 V
Degree of protection (IP) IP20
Max. PV-voltage 0.000 V
Voltage protection level N-PE 1.500 kV
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 25.000 mm²
Max. conductor cross section flexible (fine-strand) 35.000 mm²
Voltage protection level (DC+ - DC-) 0.000 kV
Voltage protection level (DC+/DC- - PE) 0.000 kV
Specific energy (W/R) 2500.000 kJ/Ohm
Energy-coordinated protection effect with regard to the terminal equipment No
System configuration DC No
System configuration IT No
System configuration TN Yes
System configuration TN-C No
System configuration TN-S Yes
System configuration TT Yes
System configuration other Yes
System configuration TN-C-S No
Voltage protection level L-PE 1.500 kV
Max. overcurrent protection device, parallel connection (fuse) 0.000 A
Max. overcurrent protection device, series connection (fuse) 0.000 A
Voltage switching spark gap technology Yes
Overcurrent protected voltage tapping No
Packing details
Packing level 1 4015081549221
Packing level 2 9008790412684
Description
For protecting consumer systems against transient overvoltages caused by direct and indirect lightning strikes and switching operations, use in accordance with IEC 60364-5-53 section 534, iI according to IEC 61643-1, SPD-type T1, T2 according to EN 61643-11, lightning protection classes III and IV as per IEC 62305, type with remote signaling