Self-learning mains disconnection relay, 1 NO contact 10A image 1

Self-learning mains disconnection relay, 1 NO contact 10A

Sandėlyje esančios prekės kaina (be PVM):
47,79 €
Ši kaina galioja iki 2024-12-31
Kaina už m: 47,79 €
EAN: 4010312203477
MPN: 61100530
Mūsų sandėlis: Ne Pardavėjo atsargos: Ne
Už pakuotę: 1 Už dėžę: 1 Už padėklą: N/A
Techniniai duomenys
Prekės būklė Nauja
Gamintojo pavadinimas Self-learning mains disconnection relay, 1 NO contact 10A
Prekės ženklas ELTAKO
Kategorijos Relės
Kilmės šalis CN
Suderintos sistemos kodas 8536 5080 00
Montavimo metodas Kita
Suprojektuotas gylis 26 mm
Nustatyta srovė 10 A
Nustatyta įtampa 250 V
Nominalus dažnis 50 Hz
Modulinių tarpų skaičius plotyje 0
Slenkstinės srovės aktyvavimas 20 mA
Maks. perjungimo srovė (cos phi = 0,6) 10 A
Maks. kaitrinės lempos apkrova 1000 W
Maks. fluorescencinės lempos apkrova 1000 VA
Maks. fluorescencinės lempos apkrova (dviguba grandinė) 1000 VA
Maks. fluorescencinės lempos apkrova (lygiagrečiai kompensuojama) 500 VA
Saugos laipsnis (IP) IP20
Įtampos stebėjimas Nuolatinė srovė
Pakavimo informacija
Pakavimo lygis 1 4010312203477, 4010312203477
Pakavimo lygis 2 4010312203477
Pakavimo lygis 3 4010312203477
Downloads
Aprašymas
1 NO contact not potential free 10A/250V AC. 230V LED lamps up to 200W, incandescent lamp load 1000W. Standby loss 0.8 watt only. Built-in device for installation. 45mm long, 45mm wide, 26mm deep. 230V supply voltage and switching voltage. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. The FR61-230V mains disconnection relay disconnects the power supply once all series connected loads are turned off, thus preventing any electromagnetic interference fields from occurring. Small loads up to 20mA are acceptable and, once major loads are disconnected, they do not prevent field disconnection. There is no need to manually set the limit. It is learned by the FR61. Loads drawing more than 200mA are consistently defined as loads which should cause the line power to be connected. As long as no major load is turned on, one pole of the monitored circuit remains isolated from the mains. Neutral and earth are connected continuously to avoid acting as an aerial. A DC voltage of 230V DC with an extremely low residual ripple is applied for monitoring. Therefore, it is prohibited to bridge the relay contact, which would ultimately cause device failure. When a load is turned on, the mains disconnection relay connects the phase. If the phase is switched on for the first time and after a power failure the FR61 automatically learns in again: At first an inrush current of 30mA is specified. If a new small load is switched on for more than 24 hours, the total current drawn by the monitored circuit is less than 200mA, and in the meantime the light has been switched on and off, the new load is learned in and the conductor is switched off. This learn-in mode can be realised immediately after connection of the new load by briefly switching off the MCB.