MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A image 1
MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A image 2
MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A image 3
MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A thumbnail 1
MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A thumbnail 2
MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A thumbnail 3

MS132-25T Circuit Breaker for Primary Transformer Protection

Yra sandėlyje: Ne Pardavėjo atsargos: Ne Minimalus užsakymo kiekis: 1
Kaina (be PVM):
33,20 € už vnt.
Ši kaina galioja iki 01.01.25
EAN: 4013614535116
MPN: 1SAM340010R1001
Pakuotė: 1
Dėžė: 28

Technical Information

Prekės būklė Nauja
Gamintojo pavadinimas MS132-0.16KT Circuit Breaker for Primary Transformer Protection 0.10 ... 0.16 A
Prekės ženklas ABB
Kategorijos Elektros automatas
Suderintos sistemos kodas 8536 2010 00
Nominali nuolatinė srovė Iu 0.16 A
Su integruotu per žemos įtampos jungikliu No
Polių skaičius 3
Apsaugos nuo perkrovos diapazono nustatymas 0.1-0.16 A
Saugos laipsnis (IP) IP20
Pagrindinės srovės grandinės jungties tipas Spyruoklinio spaustuvo jungtis
Kontrolinio elemento tipas Sukamas mygtukas (rankenėlė)
Reguliuojamo diapazono neuždelstas trumpo jungimosi atjungimas 3.2 A
Įrenginio konstrukcija Pilnas prietaisas korpuse

Pakavimo informacija

Pakavimo lygis 1 4013614535116
Pakavimo lygis 2 4013614535420

Atsisiuntimai

Aprašymas

The circuit breaker for transformer protection MS132-0.16KT is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 0.16 A with Push-In Spring terminals. It allows fuseless protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips and terminal spacers are available as accessory.