Registruokitės, kad atrakintumėte savo išskirtines B2B kainas ir pradėtumėte apsipirkinėti. Užsiregistruokite dabar!
NFB44E-14 250-500V50/60HZ-DC Contactor image 1
NFB44E-14 250-500V50/60HZ-DC Contactor image 2
NFB44E-14 250-500V50/60HZ-DC Contactor image 3
NFB44E-14 250-500V50/60HZ-DC Contactor thumbnail 1
NFB44E-14 250-500V50/60HZ-DC Contactor thumbnail 2
NFB44E-14 250-500V50/60HZ-DC Contactor thumbnail 3

NFB44E-14 250-500V50/60HZ-DC Contactor

Yra sandėlyje: Ne Pardavėjo atsargos: Ne Minimalus užsakymo kiekis: 1
Kaina (be PVM):
48,88 € už vnt.
Ši kaina galioja iki 10.01.25
EAN: 3471523105348
MPN: 1SBH137061R1444
Dėžė: 1

Technical Information

Prekės būklė Nauja
Gamintojo pavadinimas NFB44E-14 250-500V50/60HZ-DC Contactor
Prekės ženklas ABB
Kategorijos Moduliniai jungikliai
Suderintos sistemos kodas 8536 4900 00
Papildomų kontaktų, kurie įprastai yra atviri, skaičius 4
Papildomų kontaktų, kurie įprastai yra uždaryti, skaičius 4
Nominali kontrolės maitinimo įtampa, kai AC 50 Hz 250 V
Nominali kontrolės maitinimo įtampa, kai AC 60 Hz 250 V
DC nominali kontrolės maitinimo įtampa 250 V
Aktyvacijos įtampos tipas Kintamoji ar nuolatinė srovė

Pakavimo informacija

Pakavimo lygis 1 3471523105348

Atsisiuntimai

Aprašymas

The NFB44E-14 is a contactor relay complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds. It is used for switching auxiliary and control circuits. These contactor relays: • include screw terminals for connection with standard ferrules for a safe insertion and wiring of cables. • improve the compactness of the installations thanks to reduced dimension and side-by-side mounting requiring less 15% width (without spacing) from -40 °C up to +70 °C • meet all main general and rolling stocks standards: IEC 60947-5-1 and the shocks and vibration withstand conforming to IEC 61373 cat. 1, class B • reach the highest levels in fire and smoke behaviour with compliance to European standard EN 45545-2 (HL2, HL3 hazard levels) in group mounting • reduce train energy with lighter devices and requiring 68% less coil energy consumption in operation • get an electronic coil interface accepting sinusoïdal AC 50/60 Hz control supplies included inside Ucmin.... Ucmax voltage range. Max permitted AC 50/60 Hz control voltage must not be exceeded (see technical data) • include mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 and are side-marked with the "Mechanically Linked" symbol • include a wide range of auxiliary contact blocks for front and side mounting.