Registruokitės, kad atrakintumėte savo išskirtines B2B kainas ir pradėtumėte apsipirkinėti. Užsiregistruokite dabar!
MD01 image 1
MD01 image 2
MD01 image 3
MD01 image 4
KA4608 Measurement and metering transformer board, Field width: 1, Rows: 0, 1050 mm x 250 mm x 160 mm, IP2XC image 5
MD01 thumbnail 1
MD01 thumbnail 2
MD01 thumbnail 3
MD01 thumbnail 4
KA4608 Measurement and metering transformer board, Field width: 1, Rows: 0, 1050 mm x 250 mm x 160 mm, IP2XC thumbnail 5

KA4608 Mess- und Wandlerfeld BH3 vorverdrahtet mit BKE-I

Yra sandėlyje: Ne Pardavėjo atsargos: Ne Minimalus užsakymo kiekis: 1
Kaina (be PVM):
1 514,39 €
Ši kaina galioja iki 24.12.24
EAN: 4011617340393
MPN: 2CPX034039R9999
Dėžė: 1

Technical Information

Prekės būklė Nauja
Gamintojo pavadinimas KA4608 Measurement and metering transformer board, Field width: 1, Rows: 0, 1050 mm x 250 mm x 160 mm, IP2XC
Prekės ženklas ABB
Kategorijos Elektros skydai
Suderintos sistemos kodas 8537 1098 00
Spalva Pilkas
Plotis 250 mm
Modelis eHZ
Aukštis 1050 mm
RAL numeris 7035
Su montavimo plokšte No
Jungties vieta 300 mm
Su laidynu Yes
Modulinių tarpų skaičius plotyje 12
TSG panelių skaičius 0
Paskirstytojo eilių skaičius 0
Matuoklio dėžių skaičius 1
Apatinė jungties erdvė Su 5 polių šynos juosta
Saugos laipsnis (IP) IP2XC
Pagrindinio jungiklio nominali srovė 80 A
Dangčio modelis Uždarytas su spaudavimu

Pakavimo informacija

Pakavimo lygis 1 4011617340393

Atsisiuntimai

Aprašymas

Measurement and metering transformer board, fully assembled module, with BKE-I, for the internal use, degree of protection IP2XC, applicable standards: EN 61439-1, EN 61439-2, EN 61439-3, Rated operational voltage 415V AC 50/60 Hz, rated current 63 A, Rated current of the assembly of switchgear and controlgear InA 75 A, in RAL 7035, dimensions in mm (H x W x D): 1050 x 250 x 160, Earthing system TN-S, 5-pole, Stecktechnik, Number of transformer meter spaces 1, Pre-wired according requirements DSO, voltage path Miniature circuit breaker B10/25 kA 3-pole overvoltage path catagory 3, busbar system Cu busbars 12 x 5 mm 5-pole, parting point before the current transformer Fuse base elements 1x3xNH00/125 A, current transformer range Mounting plate for Single-CT for threading the cable through, parting point after the current transformer Switch 125 A / 3-pole (10-70qmm), primary wiring 35 qmm, Note: E DIN VDE 0603-2-2, Grid unit 7 GU, Overall height 3, panel width 1, Space units 84, covers out of Plastic, Quick sealable connection, RAL 7035