Technical Information
Prekės būklė |
Nauja |
Gamintojo pavadinimas |
Weather station REG-K/4-gang, light grey |
Prekės ženklas |
Schneider Electric
|
Kategorijos |
Jutikliai
|
Kilmės šalis |
DE |
Montavimo metodas |
DRA |
Spalva |
Pilkas |
EIB / KNX magistralės sistema |
Yes |
Magistralės sistemos radijo dažnis |
No |
„Powernet“ magistralės sistema |
No |
Įtraukta magistralės jungtis |
Yes |
Su šildytuvu |
No |
Skaitmeninių įvesčių skaičius |
0 |
Analoginė įvestis |
Yes |
Kitos maršrutinės sistemos |
Nėra |
LON magistralinė sistema |
No |
RAL numeris (gretimas) |
7035 |
Oro stotis |
Yes |
Saugos laipsnis (IP) |
IP20 |
Su DCF77 |
Yes |
Akustinis signalas |
No |
KNX radijo magistralės sistema |
No |
Dvikryptis radijas |
No |
Pakavimo informacija
Pakavimo lygis 1 |
3606485012346 |
Pakavimo lygis 2 |
3606485012344 |
Atsisiuntimai
Aprašymas
The weather station records and processes analogue sensor signals such as wind speed, brightness, twilight, precipitation and a DCF-77 signal. Up to four analogue sensors and the DCF-77 weather combi-sensor can be connected in any combination. If DCF-77 weather combi-sensors are used, it is possible to access a pre-configured setting in the software. The measured values are converted by the weather station into 1 byte / 2 byte telegrams (EIS 6/5 value). This enables bus devices (visualisation software, measured value displays) to access the control processes, generate signals or control weather-dependent processes. Programming is performed using the ETS tool for the weather station. Functions:-Two limit values per sensor (not for rain). Connection of multiple wind sensors. 14 signals can be evaluated. Evaluation of DCF-77 time signal (date and time). Astro function. Logic operation controller for application of limit-value-dependent actions (even external). Shading of individual façade segments. Signal monitoring of the combi-sensors with object for the following protective measures. Checking the wind signal for conclusiveness with object for the following protective measures. Selective façade shading (for 4 façades) with adjustment of the basic brightness, façade alignment, angle of opening relative to the sun. External objects for intervention in basic brightness, angle of opening and limit values: -Alarm byte. -Continuity monitoring with report on the bus. For installation on DIN rails TH35 according to EN 60715. The bus is connected using a bus connecting terminal. a data rail is not necessary. Auxiliary voltage: AC 24 V (+/-10 %). Analogue inputs: 4. Current interface: 0-20 mA, 4-20 mA. Voltage interface: 0-1 V, 0-10 V. utputs: DC 24 V, 100 mA. Device width: 4 modules, approx. 72 mm. Contents: With bus connecting terminal and cable cover. Colour: light grey.