Registruokitės, kad atrakintumėte savo išskirtines B2B kainas ir pradėtumėte apsipirkinėti. Užsiregistruokite dabar!
Similar figure image 1

Switch disconnector with fuse 32 A, size 1, 4-pole for LV HRC fuse size 000

Yra sandėlyje: Ne Pardavėjo atsargos: Taip Minimalus užsakymo kiekis: 1
Kaina (be PVM):
134,10 € už vnt.
Ši kaina galioja iki 31.12.24
EAN: 4001869535845
MPN: 3KF1403-2LB11
Dėžė: 1

Technical Information

Prekės būklė Nauja
Gamintojo pavadinimas Switch disconnector with fuse 32 A,...
Prekės ženklas Siemens
Kategorijos Jungiklių atjungikliai
Kilmės šalis CN
Suderintos sistemos kodas 8536 5080 00
Kabelio įeiga Kita
Nominali nuolatinė srovė Iu 32 A
Polių skaičius 4
Sąlygota nominali trumpo jungimosi srovė lq 100 kA
Priekinio šono apsaugos laipsnis (IP) IP20
Integruota variklio pavara No
Kaip avarinio sustabdymo versija No
Pagrindinio jungiklio versija Yes
Saugos jungiklio versija Yes
Nominali operacinė galia, kai AC-23, 400V 15 kW
Nominali trumpam laikui numatyta srovė Icw 2.5 kA
Tinka montavimui ant žemės Yes
Tinka priekinio montavimo 4 skylėms No
Tinka magistralės jungties montavimui -
Maks. nominali operacinė įtampa Ue AC 690 V
Su apsauga nuo klaidų No
Variklio pavara - pasirinktina No
Valdymo elemento padėtis Priekinė pusė
Su įrengtomis jungtimis No

Pakavimo informacija

Pakavimo lygis 1 4001869535845

Aprašymas

Switch disconnector with fuse 32 A, Size 1, 4-pole for LV HRC fuse Sz. 000 Front operating mechanism left Complete unit with direct operating mechanism gray Box terminal 3KF switch disconnector with fuses as main, EMERGENCY STOP or maintenance switch. Depending on their size, 3KF switch disconnectors with fuses enable a rated current between 32 and 800 A to be switched on and off. Furthermore, they fulfill a safety isolation function in all age circuits. 3KF switch disconnectors with fuses are optimized for complex applications in which LV HRC fuses are used. 1. Switch disconnectors with door coupling or direct operating mechanism in five sizes can be used in a variety of applications. 2. Simple retrofitting of functions possible thanks to an extensive range of accessories. 3. Reliable protection against electrical accidents by means of locking functions, touch protection and automatically interlocked fuse cover in the switched-on state. 4. Rugged technology with high short-circuit strength for high system availability. 5. Quick installation on the standard mounting rail with frame sizes up to 80 A. 6. Efficient engineering with extensive CAx data. 7. Reliable protection also for wind power plants up to 690 V + 10%.